Unlike the "real" p50 which at least makes some attempt to adjust the shape of the oxygen-hemoglobin dissociation curve according to measured variables, the p50(st) makes no such attempt.
Observe the equation for p50:
Now, the equation for p50(st) would look exactly the same, with the exception of the calculated shift.
As has been previously discussed, this is a sum of all the influences on the x-axis position of the curve, all the "Bohr's effects" (pH and pCO2) as well as the concentration of "normal" dyshaemoglobins and temperature.
If all of these were null, the only remaining measured variables required would be 2,3-DPG and weird rate dyshaemoglobins (like sulfhaemoglobin or nitrosylhaemoglobin, for example).
Therefore, the real value of p50(st) lies in the comparison between itself and p50.
Observe, the oxygen-hemoglobin dissociation curve with a hypothetical left shift.
Thus, the difference between the two values reflects the influence of Bohr's effect and temperature on the shape of the dissociation curve. This is actually a valuable piece of information, as these variables are amenable to some sort of crude adjustment. In contrast, the concentration of 2,3 -DPG is not something you can immediately address.
For my ABG analyser, one can examine this handy operations manual.
Malmberg, P. O., M. P. Hlastala, and R. D. Woodson. "Effect of increased blood-oxygen affinity on oxygen transport in hemorrhagic shock." Journal of Applied Physiology 47.4 (1979): 889-895.
Woodson, Robert D. "Physiological significance of oxygen dissociation curve shifts." Critical care medicine 7.9 (1979): 368-373.
MACDONALD, ROSEMARY. "Red cell 2, 3‐diphosphoglycerate and oxygen affinity." Anaesthesia 32.6 (1977): 544-553.
Huber, Fabienne L., et al. "Does venous blood gas analysis provide accurate estimates of hemoglobin oxygen affinity?." Annals of hematology 92.4 (2013): 517-521.