a) What does the cylinder pictured above contain?
b) What parameters are monitored during administration of the cylinder’s contents?
a) Nitric oxide 800ppm and Nitrogen
b) PO2 pulmonary artery pressure, methaemoglobin and nitrogen dioxide
The marvels and wonder of nitric oxide are discussed elsewhere.
The following adverse effects have been reported with its use:
The college recommend some monitoring:
There are some official (1997) UK guidelines for the use of nitric oxide, which recommend:
Ikaria, the only company which produces this stuff in Australia, has an excellent product information pamphlet.
Barker, Steven J., and John J. Badal. "The measurement of dyshemoglobins and total hemoglobin by pulse oximetry." Current Opinion in Anesthesiology21.6 (2008): 805-810.
Afshari, Arash, et al. "Inhaled nitric oxide for acute respiratory distress syndrome (ARDS) and acute lung injury in children and adults." Cochrane Database Syst Rev 7 (2010).
Cuthbertson, B. H., et al. "UK guidelines for the use of inhaled nitric oxide therapy in adult ICUs." Intensive care medicine23.12 (1997): 1212-1218.
Saltzman, BERNARD E. "Colorimetric microdetermination of nitrogen dioxide in the atmosphere." Anal. Chem 3 (1960): 135-136.
Fox, Terry. "Inspired and Expired Gas Monitoring." Respiratory Disease and its Management. Springer London, 2009. 121-126.